Any of these zone types will report to central station if reporting is enabled and the report code in the zone is properly programmed. 24 Hour Auxiliary will sound the keypad, but not the siren and will display zone information. 24 Hour Silent will neither sound, nor show zone information on the keypad. 24 Hour Audible will sound both the siren and the keypads and will display the zone information. When programming these zones in the Vista-128BPT, choose a 24 Hour zone type, such as 24 Hour Audible (ZT 07) 24 Hour Silent (ZT 06), or 24 Hour Auxiliary (ZT 08). In the Normally Open circuit, the 2K End of Line Resistor connects across the two terminals at the last panic switch wired in the circuit. A Form C panic could be wired in either of these configurations, at your discretion.Īs you can see, in the Normally Closed configuration, the 2K End of Line Resistor connects to one side of the last panic switch in the circuit, and only one of the zone terminals. Because hardwired zones on the Vista-128BPT require an End of Line Resistor, and we're going to program our zone as a 24 hour alarm, which will activate whether the zone is shorted or opened, and whether the system is armed or disarmed, it doesn't really matter which of these types of switches we use, but I will show both Normally Open, and Normally Closed wiring. Traditionally, Normally Open switches are used for life safety devices such as smoke detectors, Normally Closed devices are used to protect openings from burglary (a normally closed sensor tied to a door that you want to remain closed just makes logical sense) and Form C devices are typically more expensive than either of the other two options and are usually not required in this situation. The first thing you must do, in this instance, is determine which type of panic switch you want to use. Hardwired panic switches can be Normally Open (NO), Normally Closed (NC), or Form C, which means they can be wired either normally open, or normally closed. Move the jumper cap on the Alarm Panel INTERFACE module to the NO or NC position to set the desired behavior.To answer this question, we must first talk about panic switches in general. Normally open means that the circuit is open until the trigger voltage is applied to the IN terminal, which causes the relay to close. Normally Closedĭepending on the capabilities of your traditional alarm panel, the keyswitch may need to be configured Normally Open (NO) or Normally Closed (NC). The built-in relay is activated by applying 3.3V to the IN terminal, and is designed to be triggered from the Konnected Alarm Panel Add-on or Konnected Alarm Panel Pro OUT terminals. Any circuit up to 2A 30VDC or 0.3A 125VAC.The Alarm Panel INTERFACE module v2.1 features a built-in dry contact relay that can be used to actuate a keyswitch or many other things: SmartThings: Use the Konnected app to set up Built-in Dry Contact Relay In your smart home platform, configure the OUT zone as a Switch or Momentary switch to activate the relay. Connect IN terminal on the INTERFACE module to the OUT terminal or pin on the Konnected Alarm Panel, or either OUT1 or OUT2 pin on the Alarm Panel Pro. ![]() Seconds and then shut itself off the Panic button. Not all panels require a resistor, and some can be programmed to work with or without one. M52b28 wiring diagram e39 version 1 e28 goos 2 bmw diagrams free pdf s 5 car electrical insert. If the traditional panel requires a specific resistance value, wire the appropriate resistor inline with either the keyswitch zone. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |